Sign In | Join Free | My enlightcorp.com
China WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD. logo
WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
Professional High Voltage Test Equipment Manufacturer
Active Member

6 Years

Home > AC Resonant Test System >

Variable Inductance AC Resonant Test System Hydraulic Type For HV GIS Or CVT

WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.

Variable Inductance AC Resonant Test System Hydraulic Type For HV GIS Or CVT

Brand Name : Fanke

Model Number : CHX(LYY) Series

Certification : ISO9001

Place of Origin : CHINA

MOQ : One Set

Price : Negotiable

Payment Terms : L/C, T/T

Supply Ability : 2sets / 2months

Delivery Time : 45~60 working days

Packaging Details : Export standard wooden case with fumigation free

Test Principle : Variable Inductance Resonant Circuit

Usage : On-site AC Withstand Voltage Test For HV GIS or CVT

Design Feature : Fast installation and fast recycling , PD free

Component : Test reactor , control console , voltage regulator cabinet , standard voltage divider

Test Frequency : 50Hz/60Hz

Duty Cycle : 15mints

Test Accuracy : No Less Than 1.5%

Output Waveform : Good Sine Wave

Special For : On-site Test For HV or EHV GIS,CVT

Reactor Using Way : One body and Hydraulic Type for standing and recycling

Test Standard : IEC60060-1:2010;IEC 62271-203:2011 for GIS

Contact Now

Variable Inductance Resonant Withstand Voltage Test Set , Hydraulic Type HV Test Set With Resonance , CVT Testing

I. Application :


CHX-(LYY) Hydraulic Automatic Elevating Series Resonance Test Devices mainly applies to AC voltage withstand and partial discharge detecting of high voltage electrical apparatus no more than 800KV. Especially suitable for field calibration test for different level of CVT and AC voltage withstand test for different level of HV.GIS and GIL.

Fanke successfully developed AC voltage withstand and PD detection device through combination of series resonance circuit theory and altering traditional test reactor structure from technical feature of materialogy,electromagnetic property,auto machinery and hydraulic transmission,which makes field testing much more suitable and efficient

II. Scope of Application


Used for power frequency PD-free high voltage power source for field calibration test of CVT angular difference and ratio error.
Used for AC voltage withstand test and PD test of HV.GIS, HV.GIL,HV.switch, mutual inductor, and bushing with voltage no more than 800KV

III. Main Components:

  • Unibody-type excitation transformer and test reactor with Hydraulic Type platform
  • Measurement and Control console
  • Electric voltage regulator cabinet
  • Standard voltage divider with coupling

IV. Fast standing and recycling Figure

Variable Inductance AC Resonant Test System Hydraulic Type For HV GIS Or CVT

Variable Inductance AC Resonant Test System Hydraulic Type For HV GIS Or CVT

1.Multit tapped design for both reactors able to meet power frequency high voltage output needed by field calibration for CVT below 50Hz.
2.Matching up with variable-frequency power source to complete AC voltage withstand test for electrical equipment such as GIS, breaker,
mutual inductor, insulator ranges of 110KV---500KV.


V. Main feature
  • Quickly recycling or standing the HV generating part(test reactors&excitation transformer) through electro-hydraulic equipment and no need to use the lifting machine, Reduce the labor intensity and improve the test efficiency; easily avoid the transportation height of test equipment;
  • Integrated inner design for PD free high voltage test reactor and excitation transformer to save the layout space of testing field;
  • Adopts Silicone umbrella skirt for insulation materials of the shell of the HV generating part , reduces the height and optimizes volume&weight
  • of the part;
  • Special container foundation used to easily realize vehicle-mounted transportation ;Adopts Electro-hydraulic equipment with large thrust and lifting gently out of nimbleness and no swinging ;
  • The system can be provided with a particular test vehicle together(optional)

VI. General Technical Data:

Rated capacitor: 400KVA ~ 1000KVA
Rated voltage : 400KV ~ 800KV
Rated current : 1A ~ 2A
Working power : supply single phase 380V,50Hz/60Hz
System quality factor value : Q ≥ 50
Duty cycle and temperature rise : after 15mints of rated operation, the winding temperature rise ≤ 65K
Noise: ≤ 65dB
Altitude: ≤ 3000m
Environment temperature: -25℃ ~45℃,Relative humidity ≤ 90% ,no condensation
Size: see the above figure


VI.Accessories

  • Accessory box for storage accessoires
  • Input cables of power source
  • Output cables of power source
  • connection cable between excitation transformer and voltage regulator
  • connection cable between excitation transformer and control console
  • System grounding cables
  • HV output wires of the reactor
  • HV measuring cables ( the signal output cables of voltage divider )
  • HV output cables(reactor to divide,divider to test object)
  • Hydraulic Type platform
  • Corona ring for test reactor and divider
  • A final test report, a quality Certificate ,a user manual and a packing list are offered .


VII. Other Typical Model

Model Rated voltage Rated output current Rated output capacity

Application

(From 45Hz starting)

CHX-(LYY) -400KVA/400KV 200KV*2 2A@200KV 400KVA For 132KV and below class GIS
1A@400KV For 132KV and below class CVT
CHX-(LYY) -800KVA/400KV 200KV*4 4A@200KV 800KVA For 132KV and below class GIS
2A@400KV For 132KV and below class CVT
CHX-(LYY) -800KVA/400KV,800KV 400KV*2 2A@400KV 800KVA For 400KV and below class GIS
1A@800KV For 400KV and below class CVT
CHX-(LYY) -1600KVA/400KV,800KV 400KV*4 4A@400KV 1600KVA For 400KV and below class GIS
2A@800KV For 400KV and below class CVT
Special requirement can be made by order


Product Tags:

high voltage resonant test system

      

high voltage testing of electrical equipments

      
Quality Variable Inductance AC Resonant Test System Hydraulic Type For HV GIS Or CVT for sale

Variable Inductance AC Resonant Test System Hydraulic Type For HV GIS Or CVT Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)