Sign In | Join Free | My enlightcorp.com
China WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD. logo
WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
Professional High Voltage Test Equipment Manufacturer
Active Member

6 Years

Home > AC Resonant Test System >

PD Free Ac Resonant Test Set , Partial Discharge Test Equipment No More Than 10pC

WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.

PD Free Ac Resonant Test Set , Partial Discharge Test Equipment No More Than 10pC

Brand Name : Fanke

Model Number : FKWJF Series

Certification : ISO9001

Place of Origin : CHINA

MOQ : One Set

Price : Negotiable

Payment Terms : L/C, T/T

Supply Ability : 5 sets / 2months

Delivery Time : 65~90 working days

Packaging Details : Export standard wooden case with fumigation free

Test Principle : Variable Frequency Resonant Circuit

Usage : Induced Voltage Withstand And Partial Discharge Test

Design Feature : PD free Type , No More Than 10pC

Component : V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider

Test Frequency : 150Hz~200Hz Or 20~300Hz

Duty Cycle : 90mints or 180 Mints

Test Accuracy : No Less Than 1.5%

Output Waveform : Good Sine Wave

Special For : On-site Test For large capacity UHV class power transformer

Reactor Using Way : In Series Or In Parallel Connection

Test Standard : IEC60076-3-2013

Contact Now

PD Free Resonant Withstand Voltage Test Set , Transformer Induced Voltage Withstand And Partial Discharge Test

I. Products description :

FKWJF series test system is mainly used for field induced voltage withstand and partial discharging test of power transformers 110KV class and above. This system adopts PD free push-pull variable-frequency power source technique which ensure fine sine wave and proper test frequency output during testing under iron core unsaturated condition of power transformer .The system can also be designed compatible to test long distance XLPE cable or HV GIS.The above pictures is for transformer induced voltage withstand &partial discharge test system made by Fanke to testing for 220KV power transformer in the field.

Induced voltage withstand test(IVWT), also called induced overvoltage withstand test ,ACSD,ACLD, DVDF, is one of most important dielectric test of power transformers.As per IEC60076-3-2013, IVWT is necessary routine test and acceptance test ater installation for abobe 110KV Power transformer .

II. Applicable objects

  • Transformer with Graded insulation of 110KV
  • Transformers of 220KV,500KV,750KV,1000KV Class.
  • AC voltage withstand test can be made for GIS, transformers,switches,bushing and cables nomore than 1000kv if equipped with proper series resonance HV reactors.​

III. System Composition

  • PD free push-pull variable-frequency power source&observe&controlling cabinet,
  • PD free excitation transformers,
  • Loss compensation test reactor,
  • Partial discharging test instrument
  • Coupling Voltage divider
  • Necessary test accessories
IV. Technical Features
  • Linear power amplifier circuit designed, whole sine wave output, little wave distortion.
  • Multiple protection includes:discharge breakdown protection, over voltage setting protection,output short-circuit protection,start up null position protection,bridge arm amplification loop protection, power curve protection. Any kind of the above protection works, voltage output will be blocked immediately the major loop power supply will be cut off to guarantee the safety of personnel,tested objects and test system.
  • The signal source of the device is produced from dedicated chip,the output frequency stability can be as high as 0.0001Hz. and the output voltage is controlled by singlechip which guarantee the degree of instability of voltage less than 1%.
  • With setting function of test parameters such as test voltage and time, automatic and manual controlling methods.
  • With voltage automatic stabilization adjustment function, constant output of voltage when frequency regulation within the scope of settled.
  • Optical controlled,insulated completely HV and low voltage control loops.
  • Continuously adjustable in a test frequency range of 20—400Hz and with automatic look-up function of resonance frequency. Being able to set multistage of frequency detection.
  • LCD display and multiple rotary mouses controlled, friendly human-computer interface, simple and convenient for operation and wire drawing.
  • The variable frequency power source is shielded by high permeability magnetic material with ability of anti-strong disturbance of electric field and ensure the measurement accuracy and stability.
  • This device can be equipped with special test vehicle and container together


V. General Technical Data:

1 Capacity of variable-frequency power source : 3kW~450kW(Optional According to system model);
2 Rated input voltage: Three phase 380V±10%,50Hz
3 Rated output voltage of test system: Max up to 1200KV(Special spec. can be made by order)
4 Rated output current of test system: Can be made by order
5 Output test frequency: 20-400Hz
6 PD level itself : ≤ 5pCunder rated output voltage
7 Output waveform: Standard sine wave,waveform deviation factor ≤ 1%
8 Degree of instability of output voltage: ≤ 1.0%
9 Degree of instability of output frequency: ≤ 0.05%
10 Noise level: ≤ 65dB
11 Insulation level : Output/input terminal ground ≥ 3kV/AC/1min
12 Duty cycle: ≥ 3hours(Special spec. can be made by order)
13 Allowable temperature rise: Continuous working 3hours with rated load, no more than 70K
Note:Special spec. can be made by order

Product Tags:

high voltage resonant test system

      

resonant test set

      
Quality PD Free Ac Resonant Test Set , Partial Discharge Test Equipment No More Than 10pC for sale

PD Free Ac Resonant Test Set , Partial Discharge Test Equipment No More Than 10pC Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: WUHAN FANKE HAIWO HIGH VOLTAGE TECHNOLOGY CO.,LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)